{"id":3319,"date":"2021-06-25T14:58:57","date_gmt":"2021-06-25T18:58:57","guid":{"rendered":"https:\/\/www.kemitek.org\/?post_type=portfolio&#038;p=3319&#038;lang=en"},"modified":"2021-08-10T12:23:31","modified_gmt":"2021-08-10T16:23:31","slug":"reaction-calorimeter","status":"publish","type":"portfolio","link":"https:\/\/www.kemitek.org\/en\/portfolio-item\/reaction-calorimeter\/","title":{"rendered":"Reaction Calorimeter"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_heading-9ab5007a5212afe2338ce8705fc5f028\">\n#top .av-special-heading.av-av_heading-9ab5007a5212afe2338ce8705fc5f028{\npadding-bottom:20px;\nfont-size:70px;\n}\n.av-special-heading.av-av_heading-9ab5007a5212afe2338ce8705fc5f028 .av-subheading{\nfont-size:30px;\n}\n<\/style>\n<div  class='av-special-heading av-av_heading-9ab5007a5212afe2338ce8705fc5f028 av-special-heading-h1 blockquote modern-quote  avia-builder-el-0  el_before_av_one_third  avia-builder-el-first  av-inherit-size '><h1 class='av-special-heading-tag '  itemprop=\"headline\"  >Reaction calorimeter<\/h1><div class='av-subheading av-subheading_below '><p>Laboratory<\/p>\n<\/div><div class='special-heading-border'><div class='special-heading-inner-border'><\/div><\/div><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_one_third-93407bb19249d2c06b1ab9d23b9661df\">\n#top .flex_column.av-av_one_third-93407bb19249d2c06b1ab9d23b9661df{\nmargin-top:0px;\nmargin-bottom:0px;\n}\n.flex_column.av-av_one_third-93407bb19249d2c06b1ab9d23b9661df{\nborder-radius:0px 0px 0px 0px;\n-webkit-border-radius:0px 0px 0px 0px;\n-moz-border-radius:0px 0px 0px 0px;\n}\n.responsive #top #wrap_all .flex_column.av-av_one_third-93407bb19249d2c06b1ab9d23b9661df{\nmargin-top:0px;\nmargin-bottom:0px;\n}\n<\/style>\n<div class='flex_column av-av_one_third-93407bb19249d2c06b1ab9d23b9661df av_one_third  avia-builder-el-1  el_after_av_heading  el_before_av_two_third  first flex_column_div av-zero-column-padding '   ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_image-f22c974961c9bf57ba82d4b9f1c25a46\">\n.avia-image-container.av-av_image-f22c974961c9bf57ba82d4b9f1c25a46 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-av_image-f22c974961c9bf57ba82d4b9f1c25a46 av-styling-no-styling avia-align-center  avia-builder-el-2  avia-builder-el-no-sibling  '  itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><a href=\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB.jpg\" data-srcset=\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB.jpg 533w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-200x300.jpg 200w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-470x705.jpg 470w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-450x675.jpg 450w\" data-sizes=\"(max-width: 533px) 100vw, 533px\" class='avia_image' ><img width=\"533\" height=\"800\" class='wp-image-3949 avia-img-lazy-loading-not-3949 avia_image' src=\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB.jpg\" alt='' title='Calorim\u00e8tre 533x800-02-DB'  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB.jpg 533w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-200x300.jpg 200w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-470x705.jpg 470w, https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre-533x800-02-DB-450x675.jpg 450w\" sizes=\"(max-width: 533px) 100vw, 533px\" \/><\/a><\/div><\/div><\/div><\/div>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_two_third-531d5d4d3d3a74d4c56d8363993d8877\">\n#top .flex_column.av-av_two_third-531d5d4d3d3a74d4c56d8363993d8877{\nmargin-top:0px;\nmargin-bottom:0px;\n}\n.flex_column.av-av_two_third-531d5d4d3d3a74d4c56d8363993d8877{\nborder-radius:0px 0px 0px 0px;\n-webkit-border-radius:0px 0px 0px 0px;\n-moz-border-radius:0px 0px 0px 0px;\n}\n.responsive #top #wrap_all .flex_column.av-av_two_third-531d5d4d3d3a74d4c56d8363993d8877{\nmargin-top:0px;\nmargin-bottom:0px;\n}\n<\/style>\n<div class='flex_column av-av_two_third-531d5d4d3d3a74d4c56d8363993d8877 av_two_third  avia-builder-el-3  el_after_av_one_third  avia-builder-el-last  flex_column_div av-zero-column-padding '   ><section  class='av_textblock_section av-av_textblock-0366cc7376be6c9e82a3e9cc8987b64f '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '  itemprop=\"text\" ><h3>SPECIFICATIONS<\/h3>\n<ul>\n<li>Manufacturer : METTLER TOLEDO<\/li>\n<li>Model : OptIMax\u2122 HFCal<\/li>\n<li>Thermostat\u00a0:\n<ul>\n<li>Heating: Electrical<\/li>\n<li>Cooling: Peltier<\/li>\n<li>Temperature range : -40\u00b0C to 180\u00b0C<\/li>\n<li>Control Modes : Isothermal and isoperibolic, constant or ramp, reflux, distillation and crystallization<\/li>\n<li>Stirring : 30 rpm to 1200 rpm<\/li>\n<\/ul>\n<\/li>\n<li>Reactors\u00a0:\n<ul>\n<li>Type\u00a0: Single piece or two piece<\/li>\n<li>Volume\u00a0: 1000, 500 and 250 ml<\/li>\n<li>Pressure : 50 mbar to 1 bar<\/li>\n<li>Material : Duran\u00ae glass<\/li>\n<li>Stirrer : Pitch-blade, Anchor, Half-moon<\/li>\n<\/ul>\n<\/li>\n<li>Calorimetry :\n<ul>\n<li>Type\u00a0: Heat flow<\/li>\n<li>Precision Heat Transfer : Typically \u00b1 3 %<\/li>\n<li>Accuracy and Precision Specific Heat : Typically \u00b1 10 %<\/li>\n<li>Accuracy Heat Flow : Typically \u00b1 3 to 5 % (under isothermal conditions); Typically \u00b1 5 to 10 % (under non-isothermal conditions)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h3>PARTICULARITY<\/h3>\n<ul>\n<li>Accessories: Modules for dose addition, pH probe, turbidity probe<\/li>\n<\/ul>\n<h3>USE<\/h3>\n<ul>\n<li>Determining how chemical reactions can be transferred safety from the laboratory to the production site.<\/li>\n<li>OptIMax\u2122 HFCal reproducibly delivers information to characterize process parameters, for scale-up and to ensure it is safe at scale:\n<ul>\n<li>Heat transfer coefficient<\/li>\n<li>Specific heat of the reaction mass<\/li>\n<li>Heat flow for isothermal and non-isothermal conditions<\/li>\n<li>Enthalpy<\/li>\n<li>Thermal conversion<\/li>\n<li>Adiabatic temperature rise<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><\/section><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":3303,"comment_status":"closed","ping_status":"closed","template":"","tags":[],"portfolio_entries":[44,45],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.7.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Reaction Calorimeter - Kemitek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reaction Calorimeter - Kemitek\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en\" \/>\n<meta property=\"og:site_name\" content=\"Kemitek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/kemitek.ca\" \/>\n<meta property=\"article:modified_time\" content=\"2021-08-10T16:23:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre533x533-02-JG.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"533\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:site\" content=\"@Kemitek_CA\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.kemitek.org\/#website\",\"url\":\"https:\/\/www.kemitek.org\/\",\"name\":\"Kemitek\",\"description\":\"Recherche et d\\u00e9veloppement en chimie verte\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.kemitek.org\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\\u00e8tre533x533-02-JG.jpg\",\"contentUrl\":\"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\\u00e8tre533x533-02-JG.jpg\",\"width\":533,\"height\":533},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#webpage\",\"url\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en\",\"name\":\"Reaction Calorimeter - Kemitek\",\"isPartOf\":{\"@id\":\"https:\/\/www.kemitek.org\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#primaryimage\"},\"datePublished\":\"2021-06-25T18:58:57+00:00\",\"dateModified\":\"2021-08-10T16:23:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.kemitek.org\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reaction Calorimeter\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reaction Calorimeter - Kemitek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en","og_locale":"en_US","og_type":"article","og_title":"Reaction Calorimeter - Kemitek","og_url":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en","og_site_name":"Kemitek","article_publisher":"https:\/\/www.facebook.com\/kemitek.ca","article_modified_time":"2021-08-10T16:23:31+00:00","og_image":[{"width":533,"height":533,"url":"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre533x533-02-JG.jpg","type":"image\/jpeg"}],"twitter_card":"summary","twitter_site":"@Kemitek_CA","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.kemitek.org\/#website","url":"https:\/\/www.kemitek.org\/","name":"Kemitek","description":"Recherche et d\u00e9veloppement en chimie verte","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kemitek.org\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#primaryimage","inLanguage":"en-US","url":"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre533x533-02-JG.jpg","contentUrl":"https:\/\/www.kemitek.org\/wp-content\/uploads\/2021\/03\/Calorim\u00e8tre533x533-02-JG.jpg","width":533,"height":533},{"@type":"WebPage","@id":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#webpage","url":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en","name":"Reaction Calorimeter - Kemitek","isPartOf":{"@id":"https:\/\/www.kemitek.org\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#primaryimage"},"datePublished":"2021-06-25T18:58:57+00:00","dateModified":"2021-08-10T16:23:31+00:00","breadcrumb":{"@id":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.kemitek.org\/portfolio-item\/reaction-calorimeter\/?lang=en#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.kemitek.org\/en\/"},{"@type":"ListItem","position":2,"name":"Reaction Calorimeter"}]}]}},"_links":{"self":[{"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/portfolio\/3319"}],"collection":[{"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/comments?post=3319"}],"version-history":[{"count":0,"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/portfolio\/3319\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/media\/3303"}],"wp:attachment":[{"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/media?parent=3319"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/tags?post=3319"},{"taxonomy":"portfolio_entries","embeddable":true,"href":"https:\/\/www.kemitek.org\/en\/wp-json\/wp\/v2\/portfolio_entries?post=3319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}